HomePublic Utilities CodeDiv. 4Ch. 5Art. 2§ 8030 Guy Wire Insulation Requirements

§ 8030 Guy Wire Insulation Requirements

Public Utilities Code·California
AI Summary·Official Text·Key Terms·Related Statutes·References
AI SummaryVerified

§ 8030 Guy Wire Insulation Requirements

Key Takeaways

  • •Guy wires or cables attached to poles with electricity must be insulated at specific points to prevent accidents.
  • •The insulation must be placed between 4 to 8 feet from the top of the wire and at least 8 feet above the ground.
  • •If multiple guy wires are on the same pole, they must be spaced at least 1 foot apart vertically.
  • •No insulation is needed at the bottom of the wire if it's attached to a grounded anchor or if the pole is made of grounded steel and carries very high voltage (over 15,000 volts).

Example

A utility company installs guy wires to support a pole carrying electric cables in a neighborhood.

The company must ensure the guy wires are insulated 5 feet from the top and 8 feet above the ground. If they attach two guy wires to the same pole, they must space them at least 1 foot apart vertically. If the wires are attached to a grounded anchor at the bottom, no insulation is needed there.

AI-generated — May contain errors. Not legal advice. Always verify source.

Official Source
View on CA.gov

§ 8030 Guy Wire Insulation Requirements

No person shall run, place, erect, or maintain any guy wire or guy cable attached to any pole or appliance to which is attached any wire or cable used to conduct electricity, without causing the guy wire or guy cable to be effectively insulated at all times at a distance of not less than four (4) feet nor more than eight (8) feet (measured along the line of the wire or cable) from the upper end thereof, and at a point not less than eight (8) feet vertically above the ground from the lower end thereof. Where two or more guy wires or guy cables are attached to the same pole and same anchorage pole there shall be at least one foot, vertical space, between the points of attachment. No insulation shall be required at the lower end of a guy wire or guy cable where it is attached to a grounded anchor. Where guy wires or guy cables are attached to a pole or structure of steel or other conducting material supporting wires or cables conducting in excess of 15,000 volts where the pole or structure is thoroughly grounded no insulation shall be required at any point in the guy wire or guy cable. This section does not apply to guy wires or guy cables attached to poles carrying no wire or cable other than signal wires or cables and which are situated outside the corporate limits of a city. (Enacted by Stats. 1951, Ch. 764.)

Last verified: January 23, 2026

Key Terms

netportanchorinsulationapplianceelectricitydistanceattachment

Related Statutes

  • § 8026 Electrical Wire Pole Clearance
  • § 8029 High Voltage Wire Marking
  • § 8036 Electrical Span Wire Insulation
  • § 8027 Electrical Wire Pole Clearance
  • § 8028 High Voltage Wire Clearance

References

  • Official text at leginfo.legislature.ca.gov
  • California Legislature. Public Utilities Code. Section 8030.
View Official Source